هندسة مرة واحدة، نشر متعدد.
A mobile forensic lab is a road-deployable criminal investigation laboratory configured with DNA analysis, toxicology chemistry, evidence processing and chain-of-custody infrastructure for on-site or near-site forensic investigation. structmod mobile forensic lab trailers serve national police forensic services conducting field forensic operations, military forensic units supporting post-conflict investigation and mass grave analysis, counter-terrorism units processing evidence from incident sites, and specialty forensic operations (drug enforcement laboratory support, wildlife crime investigation) requiring rapid field deployment.
Standard configurations include DNA analysis bay (with pre-PCR and post-PCR contamination zones physically separated), toxicology chemistry bay (GC-MS or LC-MS instrumentation for drug analysis), evidence reception and chain-of-custody workspace (secure evidence storage, bar-coded evidence tracking, documentation), trace evidence examination (microscopy, spectroscopy for fibres, hair, glass, paint analysis), latent fingerprint development (cyanoacrylate fuming chamber, powder workstations, ALS examination), and supporting infrastructure (operator changing and PPE workflow, laboratory waste management, climate control sized to equipment heat load). Chain-of-custody is paramount — electronic evidence tracking with tamper-evident audit logging supports court-admissible forensic work.
structmod mobile forensic lab trailers serve forensic operations where field deployment matters — national police forensic services running field forensic support at major crime scenes, international criminal tribunals and war crimes investigation deploying to post-conflict zones for mass grave analysis, military forensic units supporting expeditionary operations, and specialty forensic programmes (counter-narcotics mobile testing, wildlife crime enforcement) requiring rapid field deployment. Lead time is 12-14 weeks from contract signature for stock configurations, 14-18 weeks for specialty configurations. Compliance includes ISO 17025 laboratory competence framework support, ENFSI guidelines (European Network of Forensic Science Institutes), and destination-country forensic accreditation framework.
تسلسل النشر النموذجي
- الساعة 0 — وصول المقطورة على مركبة السحب، التمركز والتثبيت
- الساعة 0–1 — فرد أرجل التثبيت والتحقق من التسوية
- الساعة 1–2 — فرد الجدران الهيدروليكية أو التوسعات حيث مثبتة
- الساعة 2–3 — توصيل المرافق (طاقة، مياه، صرف)
- الساعة 3–4 — الاختبار الوظيفي وفق بروتوكول FAT
- الساعة 4 — التسليم التشغيلي مع تدريب المستخدمين
Spec sheet — STR-2762
| الطول الكلي | 12.2 m · 40.0 ft |
|---|---|
| العرض (أثناء النقل) | 2.99 م |
| العرض (بعد الفرد) | 2.99 م |
| الارتفاع (أثناء النقل) | 2.90 م |
| مساحة الأرضية (بعد الفرد) | 36.5 m² |
| الوزن الفارغ | 17.2 t |
| الهيكل | فولاذ مُدرفل على الساخن EN 10025 S355JR · EN 1090 EXC-2 |
| جودة اللحام | EN ISO 3834-3 |
| الغلاف | لوح ساندويتش، نواة PIR 80 مم · λ ≈ 0.023 واط/(م·كلفن) |
| مقاومة الحريق | EI-30 · مُختبر وفق EN 13501-2 |
| الأرضية | خشب رقائقي بحري على EPDM · تصنيف مقاومة انزلاق R-10 |
| الكهرباء | 120/240 فولت · 60 هرتز (مواصفات أمريكية) · مطابق IEC 60364 |
| التكييف والتهوية | وحدة سقفية متكاملة · MERV-13 |
| نطاق التشغيل | −25 °م إلى +50 °م (محيط) |
| مقاومة الرياح | مُصمَّم لرياح أساسية 150 كم/س (EN 1991-1-4) |
| النقل | بصمة ISO 668 · مؤهّل للوحة CSC (الإصدارات الحاوية) |
| زمن التجهيز | 4 ساعات · طاقم شخصين |
Full drawings, calculation notes, DoP, O&M manual and FAT report included with every unit. Specs indicative — configurable to project requirements.