هندسة مرة واحدة، نشر متعدد.
A modular broadcast unit is a permanent broadcast production facility built from prefabricated modules with the studio space, control room, technical infrastructure, acoustic isolation and supporting spaces required for television, radio, podcast or streaming production. structmod modular broadcast units serve regional television and radio broadcasters expanding production capacity, sports broadcasters establishing dedicated venue facilities, corporate broadcast operators (training, internal communication, customer-facing live events), university and educational broadcasters running communications programmes, and political/news organisations setting up dedicated broadcast capability. The 12-16 week turnkey delivery is critical when broadcast launch dates drive the project schedule.
Standard configurations include studio space (typical 30-80 m² for general production, larger for major productions) with broadcast-grade acoustic isolation (typical NR-25 or quieter background noise level, 50-60 dB sound transmission class wall partitions), control room with director's desk, audio mixing position, video switching and graphics workstations, equipment rack room with broadcast servers, encoders, transmitters and patch infrastructure, presentation area for talent prep, makeup and green room, and supporting technical spaces (engineering office, IT/IP infrastructure, master control). Lighting grids in studio space support broadcast lighting (typical 50+ kg/m² ceiling load capacity for lighting fixtures).
structmod modular broadcast units serve broadcasters worldwide where rapid facility delivery matters: regional television opening news bureaus in expanding markets, sports broadcasters establishing facilities at venues, corporate communications operators, religious broadcasters expanding their coverage, and political/news organisations setting up dedicated facilities ahead of major events (elections, summits). Lead time is 12-16 weeks from contract signature for stock configurations, 14-18 weeks for configurations including major-production studios or specialty acoustic treatment. EN 1090 EXC-2 structural, IEC 60364-1 commercial electrical with broadcast-grade earthing/bonding, EMI/EMC compliance for sensitive broadcast equipment.
تسلسل النشر النموذجي
- اليوم 1 — التحقق من أساس الموقع، تركيب الأرجل الملولبة أو الأساسات الشريطية
- اليوم 2–3 — رفع الوحدات إلى مواقعها بواسطة رافعة متنقلة
- اليوم 3–4 — توصيل الوحدات وإحكام الغلاف
- اليوم 4–5 — توصيلات MEP، الاختبارات الرطبة
- اليوم 5–6 — التشطيب الداخلي، تركيب التجهيزات والمعدات
- اليوم 7 — التشغيل، تقرير FAT، تدريب المستخدمين والتسليم
Spec sheet — STR-2241
| الطول الكلي | 12.1 m · 39.7 ft |
|---|---|
| العرض (أثناء النقل) | 2.99 م |
| العرض (بعد الفرد) | 2.99 م |
| الارتفاع (أثناء النقل) | 3.00 م |
| مساحة الأرضية (بعد الفرد) | 36.2 m² |
| الوزن الفارغ | 9.1 t |
| الهيكل | فولاذ مُدرفل على الساخن EN 10025 S355JR · EN 1090 EXC-2 |
| جودة اللحام | EN ISO 3834-3 |
| الغلاف | لوح ساندويتش، نواة PIR 80 مم · λ ≈ 0.023 واط/(م·كلفن) |
| مقاومة الحريق | EI-30 · مُختبر وفق EN 13501-2 |
| الأرضية | خشب رقائقي بحري على EPDM · تصنيف مقاومة انزلاق R-10 |
| الكهرباء | 230 فولت / 50 هرتز · TN-S · مطابق IEC 60364 |
| التكييف والتهوية | مضخة حرارية Split Inverter · MERV-8 |
| نطاق التشغيل | −25 °م إلى +50 °م (محيط) |
| مقاومة الرياح | مُصمَّم لرياح أساسية 130 كم/س (EN 1991-1-4) |
| التصميم الزلزالي | وفق EN 1998-1 (يوروكود 8) · فئة مطيلية DCM |
| النقل | بصمة ISO 668 · مؤهّل للوحة CSC (الإصدارات الحاوية) |
| زمن التجهيز | 3 ساعات · طاقم شخصين |
Full drawings, calculation notes, DoP, O&M manual and FAT report included with every unit. Specs indicative — configurable to project requirements.