Engineered once, deployable many times.
A modular laboratory unit is a permanent laboratory facility built from prefabricated modules with the laboratory benches, fume cupboards, biological safety cabinets, autoclaves, equipment infrastructure and biocontainment features required for modern laboratory science. structmod modular laboratory units serve clinical pathology laboratories (hospital and reference labs), research laboratories (university and institutional research, contract research organisations), industrial quality control laboratories (pharmaceutical, food, environmental), and biocontainment facilities at BSL-2 level (BSL-3 and BSL-4 require additional engineering beyond standard modular configuration).
Standard configurations include modular lab benches (sized to standard 2-, 3-, or 4-bench configurations) with integrated services (gas, vacuum, water, electricity), fume cupboards (compliant with EN 14175), biological safety cabinets (Class II Type A2 or B2 per BSL requirement), autoclave for sterilisation, refrigerated storage for samples and reagents, dedicated zones for sample reception, processing, analysis, and storage, and supporting spaces (administration, gowning, hand-wash). HVAC follows ASHRAE 110 for fume cupboard performance and ISO 14644 cleanroom standards where required. BSL-2 biocontainment includes anteroom for PPE, autoclave for waste sterilisation, and HEPA-filtered exhaust per BSL-2 requirements.
structmod modular laboratory units serve hospital and reference clinical laboratories expanding diagnostic capacity, university and institutional research laboratories establishing new programmes, biotech and pharmaceutical companies establishing new R&D capability, and government laboratories (food safety, environmental monitoring, public health) extending technical capability. Lead time is 12-16 weeks from contract signature for stock configurations, 14-18 weeks for BSL-2 configurations or specialty laboratory configurations. Compliance includes IEC 60364-1 commercial electrical (Group 1 medical for clinical labs), EN 14175 fume cupboards, ISO 14644 cleanroom (where applicable), and ISO 17025 laboratory competence support framework.
Secuencia de despliegue típica
- Día 1 — cimentación del emplazamiento verificada, gatos de tornillo o zapatas corridas colocados
- Días 2–3 — módulos elevados a posición con grúa móvil
- Días 3–4 — conexiones entre módulos y sellado de envolvente
- Días 4–5 — conexiones MEP, pruebas húmedas
- Días 5–6 — acabados interiores, instalación de accesorios y equipos
- Día 7 — puesta en marcha, informe FAT, formación y entrega
Spec sheet — STR-1597
| Longitud total | 15.7 m · 51.5 ft |
|---|---|
| Anchura (transporte) | 2,99 m |
| Anchura (desplegado) | 2,99 m |
| Altura (transporte) | 2.80 m |
| Superficie (desplegado) | 46.9 m² |
| Peso en seco | 13.7 t |
| Chasis | Acero laminado en caliente EN 10025 S355JR · EN 1090 EXC-2 |
| Calidad de soldadura | EN ISO 3834-3 |
| Envolvente | Panel sándwich, núcleo PIR 80 mm · λ ≈ 0,023 W/(m·K) |
| Resistencia al fuego | EI-30 · ensayado según EN 13501-2 |
| Suelo | Contrachapado marino sobre EPDM · clasificación antideslizante R-10 |
| Instalación eléctrica | 400 V / 50 Hz · trifásico · conforme IEC 60364 |
| Climatización | VRF multi-split · HEPA H13 (médica) |
| Rango de operación | −25 °C a +50 °C ambiente |
| Clasificación de viento | Diseñado para viento básico de 140 km/h (EN 1991-1-4) |
| Diseño sísmico | Según EN 1998-1 (Eurocódigo 8) · clase de ductilidad DCM |
| Transporte | Huella ISO 668 · apto para placa CSC (variantes contenedor) |
| Tiempo de montaje | 4 horas · equipo de 2 personas |
Full drawings, calculation notes, DoP, O&M manual and FAT report included with every unit. Specs indicative — configurable to project requirements.