Engineered once, deployable many times.
A modular broadcast unit is a permanent broadcast production facility built from prefabricated modules with the studio space, control room, technical infrastructure, acoustic isolation and supporting spaces required for television, radio, podcast or streaming production. structmod modular broadcast units serve regional television and radio broadcasters expanding production capacity, sports broadcasters establishing dedicated venue facilities, corporate broadcast operators (training, internal communication, customer-facing live events), university and educational broadcasters running communications programmes, and political/news organisations setting up dedicated broadcast capability. The 12-16 week turnkey delivery is critical when broadcast launch dates drive the project schedule.
Standard configurations include studio space (typical 30-80 m² for general production, larger for major productions) with broadcast-grade acoustic isolation (typical NR-25 or quieter background noise level, 50-60 dB sound transmission class wall partitions), control room with director's desk, audio mixing position, video switching and graphics workstations, equipment rack room with broadcast servers, encoders, transmitters and patch infrastructure, presentation area for talent prep, makeup and green room, and supporting technical spaces (engineering office, IT/IP infrastructure, master control). Lighting grids in studio space support broadcast lighting (typical 50+ kg/m² ceiling load capacity for lighting fixtures).
structmod modular broadcast units serve broadcasters worldwide where rapid facility delivery matters: regional television opening news bureaus in expanding markets, sports broadcasters establishing facilities at venues, corporate communications operators, religious broadcasters expanding their coverage, and political/news organisations setting up dedicated facilities ahead of major events (elections, summits). Lead time is 12-16 weeks from contract signature for stock configurations, 14-18 weeks for configurations including major-production studios or specialty acoustic treatment. EN 1090 EXC-2 structural, IEC 60364-1 commercial electrical with broadcast-grade earthing/bonding, EMI/EMC compliance for sensitive broadcast equipment.
Tipik Konuşlanma Sırası
- Gün 1 — saha temeli doğrulandı, vida krikoları veya şerit temel yerleştirildi
- Gün 2–3 — modüller mobil vinçle konumuna yerleştirildi
- Gün 3–4 — modüller arası bağlantılar ve zarf sızdırmazlığı
- Gün 4–5 — MEP bağlantıları, ıslak testler
- Gün 5–6 — iç kaplama, armatür ve ekipman montajı
- Gün 7 — devreye alma, FAT raporu, kullanıcı eğitimi ve teslimat
Spec sheet — STR-2241
| Toplam uzunluk | 12.1 m · 39.7 ft |
|---|---|
| Genişlik (nakliye) | 2,99 m |
| Genişlik (konuşlandırılmış) | 2,99 m |
| Yükseklik (nakliye) | 3,00 m |
| Zemin alanı (konuşlandırılmış) | 36.2 m² |
| Boş ağırlık | 9.1 t |
| Şasi | EN 10025 S355JR sıcak hadde çelik · EN 1090 EXC-2 |
| Kaynak kalitesi | EN ISO 3834-3 |
| Zarf | Sandviç panel, PIR çekirdek 80 mm · λ ≈ 0,023 W/(m·K) |
| Yangın direnci | EI-30 · EN 13501-2'ye göre test edilmiş |
| Zemin | EPDM üzerine denizcilik kontrplak · R-10 kayma sınıfı |
| Elektrik tesisatı | 230 V / 50 Hz · TN-S · IEC 60364 uyumlu |
| İklimlendirme | Split inverter ısı pompası · MERV-8 |
| Çalışma aralığı | −25 °C ile +50 °C ortam |
| Rüzgar sınıfı | 130 km/s temel rüzgar için tasarlandı (EN 1991-1-4) |
| Sismik tasarım | EN 1998-1 (Eurokod 8) uyarınca · sünek sınıf DCM |
| Nakliye | ISO 668 ayak izi · CSC plakası uygun (konteyner varyantlar) |
| Kurulum süresi | 3 saat · 2 kişilik ekip |
Tam çizimler, hesap notları, DoP, İ&B kılavuzu ve FAT raporu her ünite ile dahildir. Özellikler gösterge niteliğindedir — proje gereksinimlerine göre yapılandırılabilir.