Engineered once, deployable many times.
A modular earthquake analysis unit is a deployable seismic field station built from prefabricated modules with the vibration-isolated foundation, electromagnetic-clean power infrastructure, sensor array and data acquisition workspace required for high-quality seismological monitoring. structmod modular earthquake analysis units serve national earthquake monitoring services (densifying seismograph networks across earthquake-prone regions), university seismology departments (research-quality field stations), aftershock monitoring deployments following major earthquakes, and induced-seismicity monitoring at hydraulic fracturing or geothermal sites.
The vibration-isolated foundation is the most engineered component — the seismograph and accompanying instruments must be decoupled from human activity and ambient vibration to achieve research-quality measurements. structmod modular earthquake analysis units integrate an isolated concrete pier or slab founded on bedrock or stable subsoil, structurally independent from the building floor. Sensor pads accept three-component broadband seismometers, accelerometers (for strong-motion recording during large events), and supplementary instruments (GNSS for crustal deformation, electric and magnetic field sensors where geomagnetic monitoring is included). Clean-power infrastructure delivers electromagnetically-quiet 24V DC for instruments through dedicated battery banks with charge controllers — protecting recordings from grid switching transients.
structmod modular earthquake analysis units serve seismic monitoring programmes worldwide, with particular deployment intensity in earthquake-prone regions: Türkiye (TBDY 2019 seismic monitoring densification following the 2023 Kahramanmaraş earthquakes), the Mediterranean basin, the Caucasus, the Himalayas, the Pacific Ring of Fire, and the East African Rift. Lead time is 10-12 weeks from contract signature. Sensor selection (which broadband seismometer, which strong-motion accelerometer, which timing source) is specified by the operating service against the monitoring programme's frequency band requirements and dynamic range targets. Compliance follows IEC 60364-1 commercial electrical and any operating service technical requirements.
Tipik Konuşlanma Sırası
- Gün 1 — saha temeli doğrulandı, vida krikoları veya şerit temel yerleştirildi
- Gün 2–3 — modüller mobil vinçle konumuna yerleştirildi
- Gün 3–4 — modüller arası bağlantılar ve zarf sızdırmazlığı
- Gün 4–5 — MEP bağlantıları, ıslak testler
- Gün 5–6 — iç kaplama, armatür ve ekipman montajı
- Gün 7 — devreye alma, FAT raporu, kullanıcı eğitimi ve teslimat
Spec sheet — STR-3274
| Toplam uzunluk | 15.4 m · 50.5 ft |
|---|---|
| Genişlik (nakliye) | 2,99 m |
| Genişlik (konuşlandırılmış) | 2,99 m |
| Yükseklik (nakliye) | 3.10 m |
| Zemin alanı (konuşlandırılmış) | 46.0 m² |
| Boş ağırlık | 16.4 t |
| Şasi | EN 10025 S355JR sıcak hadde çelik · EN 1090 EXC-2 |
| Kaynak kalitesi | EN ISO 3834-3 |
| Zarf | Sandviç panel, PIR çekirdek 80 mm · λ ≈ 0,023 W/(m·K) |
| Yangın direnci | EI-30 · EN 13501-2'ye göre test edilmiş |
| Zemin | EPDM üzerine denizcilik kontrplak · R-10 kayma sınıfı |
| Elektrik tesisatı | 400 V / 50 Hz · 3 fazlı · IEC 60364 uyumlu |
| İklimlendirme | VRF çok bölmeli · HEPA H13 (tıbbi) |
| Çalışma aralığı | −25 °C ile +50 °C ortam |
| Rüzgar sınıfı | 140 km/s temel rüzgar için tasarlandı (EN 1991-1-4) |
| Sismik tasarım | EN 1998-1 (Eurokod 8) uyarınca · sünek sınıf DCM |
| Nakliye | ISO 668 ayak izi · CSC plakası uygun (konteyner varyantlar) |
| Kurulum süresi | Sahada 2–7 gün |
Tam çizimler, hesap notları, DoP, İ&B kılavuzu ve FAT raporu her ünite ile dahildir. Özellikler gösterge niteliğindedir — proje gereksinimlerine göre yapılandırılabilir.