GENEL BAKIŞ

Engineered once, deployable many times.

A modular laboratory unit is a permanent laboratory facility built from prefabricated modules with the laboratory benches, fume cupboards, biological safety cabinets, autoclaves, equipment infrastructure and biocontainment features required for modern laboratory science. structmod modular laboratory units serve clinical pathology laboratories (hospital and reference labs), research laboratories (university and institutional research, contract research organisations), industrial quality control laboratories (pharmaceutical, food, environmental), and biocontainment facilities at BSL-2 level (BSL-3 and BSL-4 require additional engineering beyond standard modular configuration).

Standard configurations include modular lab benches (sized to standard 2-, 3-, or 4-bench configurations) with integrated services (gas, vacuum, water, electricity), fume cupboards (compliant with EN 14175), biological safety cabinets (Class II Type A2 or B2 per BSL requirement), autoclave for sterilisation, refrigerated storage for samples and reagents, dedicated zones for sample reception, processing, analysis, and storage, and supporting spaces (administration, gowning, hand-wash). HVAC follows ASHRAE 110 for fume cupboard performance and ISO 14644 cleanroom standards where required. BSL-2 biocontainment includes anteroom for PPE, autoclave for waste sterilisation, and HEPA-filtered exhaust per BSL-2 requirements.

structmod modular laboratory units serve hospital and reference clinical laboratories expanding diagnostic capacity, university and institutional research laboratories establishing new programmes, biotech and pharmaceutical companies establishing new R&D capability, and government laboratories (food safety, environmental monitoring, public health) extending technical capability. Lead time is 12-16 weeks from contract signature for stock configurations, 14-18 weeks for BSL-2 configurations or specialty laboratory configurations. Compliance includes IEC 60364-1 commercial electrical (Group 1 medical for clinical labs), EN 14175 fume cupboards, ISO 14644 cleanroom (where applicable), and ISO 17025 laboratory competence support framework.

Tipik Konuşlanma Sırası

  1. Gün 1 — saha temeli doğrulandı, vida krikoları veya şerit temel yerleştirildi
  2. Gün 2–3 — modüller mobil vinçle konumuna yerleştirildi
  3. Gün 3–4 — modüller arası bağlantılar ve zarf sızdırmazlığı
  4. Gün 4–5 — MEP bağlantıları, ıslak testler
  5. Gün 5–6 — iç kaplama, armatür ve ekipman montajı
  6. Gün 7 — devreye alma, FAT raporu, kullanıcı eğitimi ve teslimat
TEKNİK ÖZELLİKLER

Spec sheet — STR-1597

Toplam uzunluk15.7 m · 51.5 ft
Genişlik (nakliye)2,99 m
Genişlik (konuşlandırılmış)2,99 m
Yükseklik (nakliye)2.80 m
Zemin alanı (konuşlandırılmış)46.9 m²
Boş ağırlık13.7 t
ŞasiEN 10025 S355JR sıcak hadde çelik · EN 1090 EXC-2
Kaynak kalitesiEN ISO 3834-3
ZarfSandviç panel, PIR çekirdek 80 mm · λ ≈ 0,023 W/(m·K)
Yangın direnciEI-30 · EN 13501-2'ye göre test edilmiş
ZeminEPDM üzerine denizcilik kontrplak · R-10 kayma sınıfı
Elektrik tesisatı400 V / 50 Hz · 3 fazlı · IEC 60364 uyumlu
İklimlendirmeVRF çok bölmeli · HEPA H13 (tıbbi)
Çalışma aralığı−25 °C ile +50 °C ortam
Rüzgar sınıfı140 km/s temel rüzgar için tasarlandı (EN 1991-1-4)
Sismik tasarımEN 1998-1 (Eurokod 8) uyarınca · sünek sınıf DCM
NakliyeISO 668 ayak izi · CSC plakası uygun (konteyner varyantlar)
Kurulum süresi4 saat · 2 kişilik ekip

Tam çizimler, hesap notları, DoP, İ&B kılavuzu ve FAT raporu her ünite ile dahildir. Özellikler gösterge niteliğindedir — proje gereksinimlerine göre yapılandırılabilir.