GENEL BAKIŞ

Engineered once, deployable many times.

A modular workshop unit is a heavy-duty industrial facility built from prefabricated modules with the structural capacity, electrical infrastructure, ventilation and equipment provisions required for industrial workshop operations — vehicle and equipment maintenance, metal fabrication and welding, mechanical assembly, electrical assembly, woodworking, or specialised manufacturing. structmod modular workshop units serve mining and oil & gas operators establishing site maintenance facilities, defence forces standing up vehicle workshops at deployed bases, manufacturing companies establishing production lines at new locations, and infrastructure projects (construction, utilities) requiring on-site workshop capability.

Standard configurations include workshop bays sized to the equipment being serviced (typically 6-8 m clear height for large vehicle access, 4-6 m for general workshop use), 3-phase electrical infrastructure sized to workshop equipment load (typical 80-200 kVA per workshop bay), compressed air distribution to multiple service points, exhaust extraction for welding fume and engine emissions per EN 12792 and EN ISO 16110-2, overhead crane support beam where lifting capability is required (typical 2-5 tonne crane capacity), parts and tool storage with appropriate security, office and administration space for workshop management, and lockers/changing facilities for workshop staff. Workshop floor finish is heavy-duty concrete or epoxy resin per equipment access and chemical resistance requirements.

structmod modular workshop units serve operators across mining, oil & gas, defence, manufacturing and infrastructure where workshop capability needs to deploy with the operating site. Lead time is 10-14 weeks from contract signature for stock configurations, 12-16 weeks for configurations with overhead crane integration or specialty equipment provisions. EN 1090 EXC-2 structural steel sized to the workshop loads (including crane loads where fitted), IEC 60364-1 commercial/industrial electrical with appropriate earth fault protection, fire safety per workshop fire-load classification, and ventilation per industrial ventilation standards.

Tipik Konuşlanma Sırası

  1. Gün 1 — saha temeli doğrulandı, vida krikoları veya şerit temel yerleştirildi
  2. Gün 2–3 — modüller mobil vinçle konumuna yerleştirildi
  3. Gün 3–4 — modüller arası bağlantılar ve zarf sızdırmazlığı
  4. Gün 4–5 — MEP bağlantıları, ıslak testler
  5. Gün 5–6 — iç kaplama, armatür ve ekipman montajı
  6. Gün 7 — devreye alma, FAT raporu, kullanıcı eğitimi ve teslimat
TEKNİK ÖZELLİKLER

Spec sheet — STR-2187

Toplam uzunluk14.7 m · 48.2 ft
Genişlik (nakliye)2,99 m
Genişlik (konuşlandırılmış)2,99 m
Yükseklik (nakliye)3,00 m
Zemin alanı (konuşlandırılmış)44.0 m²
Boş ağırlık9.7 t
ŞasiEN 10025 S355JR sıcak hadde çelik · EN 1090 EXC-2
Kaynak kalitesiEN ISO 3834-3
ZarfSandviç panel, PIR çekirdek 80 mm · λ ≈ 0,023 W/(m·K)
Yangın direnciEI-30 · EN 13501-2'ye göre test edilmiş
ZeminEPDM üzerine denizcilik kontrplak · R-10 kayma sınıfı
Elektrik tesisatı230 V / 50 Hz · TN-S · IEC 60364 uyumlu
İklimlendirmeSplit inverter ısı pompası · MERV-8
Çalışma aralığı−25 °C ile +50 °C ortam
Rüzgar sınıfı130 km/s temel rüzgar için tasarlandı (EN 1991-1-4)
Sismik tasarımEN 1998-1 (Eurokod 8) uyarınca · sünek sınıf DCM
NakliyeISO 668 ayak izi · CSC plakası uygun (konteyner varyantlar)
Kurulum süresi4 saat · 2 kişilik ekip

Tam çizimler, hesap notları, DoP, İ&B kılavuzu ve FAT raporu her ünite ile dahildir. Özellikler gösterge niteliğindedir — proje gereksinimlerine göre yapılandırılabilir.